Models Covered

Part No. Description Min. depth behind panel
58090000 Single, control panel Min. 40 mm
58090001 Single alloy, control panel Min. 70 mm
58090002 Dual, control panel Min. 40 mm
58090003 Dual alloy, control panel Min. 70 mm

Installing the Control Panel

  • Cut the hole with a 64mm (2 1/2") hole saw. Check there is enough depth for the panel and access for the switch leads and plug.
  • The panel has a pre-installed seal and is secured with the 4 screws in the pack.
  • The shaded fixing holes on the templates are for the plastic controllers only: do not use them for the alloy panels.

The cutting templates are drawn in the PDF; print it at 1:1 (actual size, no scaling) and check the printed dimensions with a ruler before cutting.

Wiring

Part No. Description
58090019 Splitter assy Ask us to source it →
58090009 Panel/aux loom 2M Ask us to source it →
58090010 Panel/aux loom 7M Ask us to source it →
58090011 Panel/aux loom 10M Ask us to source it →
58090012 Panel/aux loom 18M Ask us to source it →
58090013 Panel/aux loom 22M Ask us to source it →
  • Control direction wrong? Open the back of the controller and move the matching direction switch on the back of the PCB.
  • With an automatic switch fitted, main power is switched on when thrusting.

On / Off and LED

  • On: press and hold ON for 1 second; LED turns green.
  • Off: press ON once; the system and LED switch off immediately.
  • In fault mode (solid red) pressing ON turns the system off.
LED Status
Green System ON
Green (flashing) RT thruster extending / retracting
Red (flashing) Motor high temperature
Red Fault

Safety Features

  • Thrusting constantly in one direction for more than 3 minutes puts the system in fault mode (red LED).
  • A PORT/STBD signal present at switch-on also gives fault mode, so a wiring fault or a second joystick cannot thrust on start-up.
  • PORT and STBD signals together stop thrusting.
  • Automatic power-down after 15 minutes of inactivity for TT and 5 minutes for RT thrusters.
  • Motor and controller have temperature monitoring; on over-temperature the system enters a limp-home mode.

Final Checks

  • Power OFF while checking. Motor connections tight with rubber boots in place; correct fuse fitted; switch wires on the correct motor terminals. Then connect to the battery.
  • Batteries fully charged before switching on main power; first runs away from other boats.
  • Never run the thruster out of the water, and never near swimmers. See the TT or RT thruster manual for more.