INSTALLATION MANUAL
Panel cut-outs and depths, loom and splitter part numbers, switching on and off, LED diagnostics and the built-in safety features of the Lewmar proportional thruster control panels 58090000 to 58090003.
DocumentLewmar Proportional Thruster Control Assemblies Installation Manual
FormatPDF · 8 pages · 1.2 MB
LanguageEnglish

Models Covered
| Part No. | Description | Min. depth behind panel |
|---|---|---|
| 58090000 | Single, control panel | Min. 40 mm |
| 58090001 | Single alloy, control panel | Min. 70 mm |
| 58090002 | Dual, control panel | Min. 40 mm |
| 58090003 | Dual alloy, control panel | Min. 70 mm |
Installing the Control Panel
- Cut the hole with a 64mm (2 1/2") hole saw. Check there is enough depth for the panel and access for the switch leads and plug.
- The panel has a pre-installed seal and is secured with the 4 screws in the pack.
- The shaded fixing holes on the templates are for the plastic controllers only: do not use them for the alloy panels.
The cutting templates are drawn in the PDF; print it at 1:1 (actual size, no scaling) and check the printed dimensions with a ruler before cutting.
Wiring
| Part No. | Description | |
|---|---|---|
| 58090019 | Splitter assy | Ask us to source it → |
| 58090009 | Panel/aux loom 2M | Ask us to source it → |
| 58090010 | Panel/aux loom 7M | Ask us to source it → |
| 58090011 | Panel/aux loom 10M | Ask us to source it → |
| 58090012 | Panel/aux loom 18M | Ask us to source it → |
| 58090013 | Panel/aux loom 22M | Ask us to source it → |
- Control direction wrong? Open the back of the controller and move the matching direction switch on the back of the PCB.
- With an automatic switch fitted, main power is switched on when thrusting.
On / Off and LED
- On: press and hold ON for 1 second; LED turns green.
- Off: press ON once; the system and LED switch off immediately.
- In fault mode (solid red) pressing ON turns the system off.
| LED | Status |
|---|---|
| Green | System ON |
| Green (flashing) | RT thruster extending / retracting |
| Red (flashing) | Motor high temperature |
| Red | Fault |
Safety Features
- Thrusting constantly in one direction for more than 3 minutes puts the system in fault mode (red LED).
- A PORT/STBD signal present at switch-on also gives fault mode, so a wiring fault or a second joystick cannot thrust on start-up.
- PORT and STBD signals together stop thrusting.
- Automatic power-down after 15 minutes of inactivity for TT and 5 minutes for RT thrusters.
- Motor and controller have temperature monitoring; on over-temperature the system enters a limp-home mode.
Final Checks
- Power OFF while checking. Motor connections tight with rubber boots in place; correct fuse fitted; switch wires on the correct motor terminals. Then connect to the battery.
- Batteries fully charged before switching on main power; first runs away from other boats.
- Never run the thruster out of the water, and never near swimmers. See the TT or RT thruster manual for more.
Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.