Specifications

Part no. Model Tunnel kW / hp Gearbox Propeller Thrust kgf / lbs Weight kg / lbs Fuse – part no.
59111001 RT140 2.0 kW 12v 140 2.0 / 2.7 Composite Single 5 blade 37 / 82 29.2 / 65 200A – 589012
59111002 RT140 2.2 kW 12v 140 2.2 / 3.0 Composite Single 5 blade 42 / 93 29.2 / 65 200A – 589012
59111003 RT140 2.0 kW 12v IP 140 2.0 / 2.8 Composite Single 5 blade 37 / 82 30 / 66 200A – 589012
59111004 RT140 2.2 kW 12v IP 140 2.2 / 3.0 Composite Single 5 blade 42 / 93 30 / 66 200A – 589012
59112004 RT185 4.0 kW 12v 185 4.0 / 5.4 Brass Dual 5 blade 65 / 143 44.8 / 99 400A – 589010
59112005 RT185 4.0 kW 24v/12v 185 4.0 / 5.4 Brass Dual 5 blade 65 / 143 43 / 95 130A – 589007
59112006 RT185 4.0 kW 24v 185 4.0 / 5.4 Brass Dual 5 blade 65 / 143 43 / 95 130A – 589007
59112007 RT185 5.0 kW 12v 185 5.0 / 6.7 Brass Dual 5 blade 82 / 181 53.4 / 118 400A – 589010
59112008 RT185 5.0 kW 24v/12v 185 5.0 / 6.7 Brass Dual 5 blade 82 / 181 51.4 / 114 130A – 589007
59112009 RT185 5.0 kW 24v 185 5.0 / 6.7 Brass Dual 5 blade 82 / 181 51.4 / 114 130A – 589007
59112010 RT185 6.0 kW 12v 185 6.0 / 8.0 Brass Dual 5 blade 97 / 214 53 / 117 500A – 589011
59112011 RT185 6.0 kW 24v/12v 185 6.0 / 8.0 Brass Dual 5 blade 97 / 214 51.5 / 114 325A – 589009
59112012 RT185 6.0 kW 24v 185 6.0 / 8.0 Brass Dual 5 blade 97 / 214 51.5 / 114 325A – 589009
59112013 RT185 Hyd 12v 185 7.0 / 10.0 Brass Dual 5 blade 100 / 220 33 / 73 –
59112014 RT185 Hyd 24v 185 7.0 / 10.0 Brass Dual 5 blade 100 / 220 33 / 73 –
59112019 RT185 4.0 kW 12v IP 185 4.0 / 5.4 Brass Dual 5 blade 65 / 143 46.3 / 102 400A – 589010
59112020 RT185 4.0 kW 24v/12v IP 185 4.0 / 5.4 Brass Dual 5 blade 65 / 143 44.5 / 98 130A – 589007
59112021 RT185 4.0 kW 24v IP 185 4.0 / 5.4 Brass Dual 5 blade 65 / 143 44.5 / 98 130A – 589007
59112022 RT185 5.0 kW 12v IP 185 5.0 / 6.7 Brass Dual 5 blade 82 / 181 54.9 / 121 400A – 589010
59112023 RT185 5.0 kW 24v/12v IP 185 5.0 / 6.7 Brass Dual 5 blade 82 / 181 52.9 / 117 130A – 589007
59112024 RT185 5.0 kW 24v IP 185 5.0 / 6.7 Brass Dual 5 blade 82 / 181 52.9 / 117 130A – 589007
59112025 RT185 6.0 kW 12v IP 185 6.0 / 8.0 Brass Dual 5 blade 97 / 214 54.5 / 120 500A – 589011
59112026 RT185 6.0 kW 24v/12v IP 185 6.0 / 8.0 Brass Dual 5 blade 97 / 214 53 / 117 325A – 589009
59112027 RT185 6.0 kW 24v IP 185 6.0 / 8.0 Brass Dual 5 blade 97 / 214 53 / 117 325A – 589009
59113001 RT250 8.0 kW 24v/12v 250 8.0 / 10.8 Bronze Twin CR 5 blade 140 / 308 107 / 236 400A – 589010
59113002 RT250 8.0 kW 24v 250 8.0 / 10.8 Bronze Twin CR 5 blade 140 / 308 107 / 236 400A – 589010
59113005 RT250 Hyd 12v 250 15.0 / 20.0 Bronze Twin CR 5 blade 200 / 440 74 / 163 –
59113006 RT250 Hyd 24v 250 15.0 / 20.0 Bronze Twin CR 5 blade 200 / 440 74 / 163 –

Fuse holders: T1 – 589006, T2 – 589013 (specification table header). The RT140 2.0 kW IP version is listed at 2.8 hp (as printed).

Installing the Thruster

  • Tunnel installation and hull modifications by a specialist; the watertight compartment must carry the thruster weight and thrust loads, ideally designed by a naval architect.
  • Bow installation: as far forward as possible. With the leg lowered, the hub centre-line must be at least 1.5 × propeller diameter below the waterline and clear of the hull.
  • Keep the compartment dry, ventilated if possible, and free of loose items that could jam the raise/lower mechanism or the stop switches.
  • Cut the hull opening with a jigsaw at 45° on all sides; keep the lower flange as level as possible and glass/bond it in without protruding into the tunnel path.
  • Lift with strops; never by the actuator or propeller shroud.
RT model (A) Minimum height mm (B) Minimum width mm Minimum depth mm
140 82 220 265
185 88 235 330
250 110 325 460
Fixing Torque
Upper housing to lower flange: M10 hex bolts; actuator bracket M10 socket caps 30 Nm
Motor to mount plate: 4 × M10 screws and nuts (RT140/185 align the shear pin; RT250 align the keyway) 43 Nm (±3 Nm)
Closing door piece to adjustment plate (M10 nyloc, not supplied) 43 Nm
Motor terminal nuts (13 mm spanner RT140, 17 mm RT185–RT250) 20 Nm (15 lbs.ft)
Actuator cam retaining nut 4 Nm
Microswitch cover 3 Nm
  • Motor points toward the bow. Do not disturb the housing gasket when seating the upper assembly.
  • Re-use the hull cut-out as the closing piece, with a moulded landing so it locates when retracted; support the door fully from bracket to tunnel.
  • Actuator travel is set to maximum at the factory; adjust the screws on the actuator cam if needed (RT250: port side only) and re-check after the first 10/15 cycles. The RT deploys as soon as the control panel is switched on.

Wiring

Model Voltage (V) Stated current (A) Circuit breaker (A) Min cable CSA mm² Max cable length (m) at min size
ICU 12 8 – 2.5 15
ICU 24 8 – 1 15
140 2.0 kW 12 280 200 70 14
140 2.2 kW 12 280 200 70 13
185 4 kW 12 470 400 150 17
185 4 kW 24 235 130 70 32
185 5 kW 12 480 400 150 17
185 5 kW 24 240 130 70 31
185 6 kW 12 700 500 150 11
185 6 kW 24 370 325 120 36
250 8 kW 24 500 400 150 33
  • Cable length is the total from the battery to the thruster and back. Use cable insulation rated 90°C or higher.
  • The ICU needs its own supply and return, cable rated for 8 amps and not over 4 mm² / 12 AWG; it has an internal slow-blow fuse. Mount it vertical (arrow on the lid), dry, away from the motor and within 5 meters of it.
  • RT to ICU: wire kit 2 meter 589808 or 5 meter 589809 (not included), into the THRUSTER port. Hydraulic installs: wire the marked loom cores directly to the valve.
  • Motor: own battery supply with battery switch, in-line fuse and breaker; ring terminals 8 mm (5/16") RT140, 10 mm (3/8") RT185 and RT250; supplied insulating boots fitted, no bare wire.
  • Battery crank capacity at least equal to the thruster current. Minimum voltage at the running motor 10V (12V units) and 21V (24V units).
  • Electrolytic test: with the negative off, no continuity from either stud to the motor body; with power on, no supply voltage between the –VE stud and the body.
  • Control panel: 63.5 mm (2 1/2") hole saw. The auxiliary wire is only for an automatic battery switch (12v 589810 / 24v 589830).

Operation and Safety Features

Using the RT

  • Hold ON for 1 second: the LED flashes green while the leg deploys and turns solid when down. Press ON once to retract and switch off.
  • More than 3 minutes thrusting one way, or a PORT/STBD signal at switch-on, puts the system in fault mode (red).
  • Simultaneous PORT and STBD signals stop thrust; reversing has a short delay for the propeller to stop.
  • Automatic power down after 5 minutes idle. A thermal switch stops the motor when hot (flashing red).
  • Never run the thruster out of the water: the motor over-speeds by 300%.

Panel LED

Colour Status
Green (flashing) RT extending / retracting
Green System on
Amber Low voltage (indication only)
Red (flashing) Motor high temperature
Red Fault
Black Off / no power source

Service Schedule

  • New install: check the anode after about 3 – 4 months to set a replacement interval.
  • Annually: clear debris from tunnel, propeller and hub; replace the anode; replace a damaged propeller; grease the exposed seal and shaft; replace the tunnel gasket if the hub is removed; check leads, torques and that the compartment is dry.
  • Electric: brush carbon dust off the top of the motor. Hydraulic: follow the system supplier.
  • Drive pin: punch out the old pin, tap in a new one and secure with a new cable tie.

Fault Finding

  • Will not turn on: check the ICU health LED (replace the ICU fuse if not flashing) and its battery cables.
  • Green then solid red: actuator travel not completed in time; check the down switch, actuator wiring and UP/DOWN switch adjustment.
  • Wrong direction: swap the contactor wires on the motor solenoid.
  • Fuse blows: wrong fuse rating, or a jammed propeller / missing propeller washer.
  • Poor thrust: batteries or cables too small, blockage, propeller washers wrong, brushes, D1/D2 terminals.
  • Motor turns, no drive: stop; replace the shear pin or broken propeller.
  • Noisy: propeller touching the tunnel; on 140-185 check hub height.

Spare Kits

RT140

Part no. Description
581111 140 2.0 kW 12V motor Ask us to source it →
581112 140 2.2 kW 12V motor Ask us to source it →
581113 140 2.0 kW 12V IP motor Ask us to source it →
581114 140 2.2 kW 12V IP motor
589151 140 propeller View part →
589157 140 thruster prop fixing kit View part →
589296 RT Gen2 I.C.U. assy View part →
589808 Gen2 RT motor loom 2 m View part →
589809 Gen2 RT motor loom 5 m Ask us to source it →
56110001 RT 140 drive shaft kit Ask us to source it →
56110004 RT 140 gearbox Ask us to source it →
56110007 RT 140 cam mech with link Ask us to source it →
56110010 RT 140 tunnel assy with bracket Ask us to source it →
56110013 RT actuator shear pin kit Ask us to source it →
56110014 RT 140 actuator 12V kit Ask us to source it →
56110019 RT 140 / 185 micro switch assy View part →
56110021 RT micro switch cover Ask us to source it →
56110022 RT 140 / 185 wire loom View part →
56110026 RT 140 anode kit Ask us to source it →
56110029 RT 140 lower flange Ask us to source it →
56110032 RT 140 shear pin kit Ask us to source it →

Lewmar RT140 exploded view

RT185

Part no. Description
583041 185 hyd motor Ask us to source it →
583084 185 4.0 kW 12V MX Ask us to source it →
583085 185 4.0 kW 24V MX Ask us to source it →
583086 185 5.0 kW 12V MX Ask us to source it →
583087 185 5.0 kW 24V MX Ask us to source it →
583088 185 6.0 kW 12V MX Ask us to source it →
583089 185 6.0 kW 24V MX Ask us to source it →
583092 185 4.0 kW 12V MX IP Ask us to source it →
583093 185 4.0 kW 24V MX IP Ask us to source it →
583094 185 5.0 kW 12V MX IP Ask us to source it →
583095 185 5.0 kW 24V MX IP Ask us to source it →
583096 185 6.0 kW 12V MX IP Ask us to source it →
583097 185 6.0 kW 24V MX IP Ask us to source it →
589351 185 propeller View part →
589296 RT Gen2 I.C.U. assy View part →
589808 Gen2 RT motor loom 2 m View part →
589809 Gen2 RT motor loom 5 m Ask us to source it →
56110002 RT 185 drive shaft kit Ask us to source it →
56110005 RT 185 gearbox Ask us to source it →
56110008 RT 185 cam mech with link Ask us to source it →
56110011 RT 185 tunnel assy with bracket Ask us to source it →
56110013 RT actuator shear pin kit Ask us to source it →
56110014 RT actuator 12V kit Ask us to source it →
56110015 RT actuator 24V kit Ask us to source it →
56110019 RT 140 / 185 micro switch assy View part →
56110021 RT micro switch cover Ask us to source it →
56110022 RT 140 / 185 wire loom View part →
56110023 RT 140 / 185 hyd wire loom Ask us to source it →
56110027 RT 185 anode kit Ask us to source it →
56110030 RT 185 lower flange Ask us to source it →
56110029 RT 185 shear pin kit (number as printed; also used for the RT 140 lower flange) Ask us to source it →

Lewmar RT185 exploded view

RT250

Part no. Description
585029 250 8.0 kW 24V motor assy MX Ask us to source it →
585041 250 hyd motor assy Ask us to source it →
589296 RT Gen2 I.C.U. assy View part →
589551 250 STBD propeller + washer
589552 250 PORT propeller + washer
589808 Gen2 RT motor loom 2 m View part →
589809 Gen2 RT motor loom 5 m Ask us to source it →
56110003 RT 250 drive shaft kit Ask us to source it →
56110006 RT 250 gearbox Ask us to source it →
56110009 RT 250 cam mech with link, port Ask us to source it →
56110012 RT 250 tunnel assy with bracket Ask us to source it →
56110013 RT actuator shear pin kit Ask us to source it →
56110016 RT 250 actuator 12V kit Ask us to source it →
56110017 RT 250 cam mech with link, stbd Ask us to source it →
56110018 RT 250 actuator 24V kit Ask us to source it →
56110020 RT 250 micro switch assy Ask us to source it →
56110021 RT micro switch cover Ask us to source it →
56110024 RT 250 wire loom Ask us to source it →
56110025 RT 250 hyd wire loom Ask us to source it →
56110028 RT 250 anode kit Ask us to source it →
56110031 RT 250 lower flange Ask us to source it →
56110034 RT 250 shear pin & drive key kit Ask us to source it →

Lewmar RT250 exploded view

Accessories

Part no. Description
589222 Controller, dual pad View part →
589223 Controller, single pad View part →
589267 Controller, dual joystick View part →
589268 Controller, single joystick View part →
589845 Controller, single, hyd Ask us to source it →
589846 Controller, dual, hyd Ask us to source it →
589809 5 m RT motor loom MX Ask us to source it →
589800 Gen2 Y loom MX View part →
589801 Gen2 AUX 2 m loom MX
589802 Gen2 AUX 7 m loom MX
589803 Gen2 AUX 10 m loom MX
589804 Gen2 AUX 18 m loom MX
589805 Gen2 AUX 22 m loom MX
589006 Fuse holder Ask us to source it →
589010 T2 fuse holder (as printed; 589010 is also the 400 A fuse)
589861 3-button remote (Gen2 system) Ask us to source it →
589862 5-button remote (Gen2 system) Ask us to source it →
56110035 RT installation nut holder Ask us to source it →
589007 130 A ANL type fuse View part →
589008 250 A ANL type fuse View part →
589009 325 A ANL type fuse View part →
589010 400 A ANL type fuse View part →
589011 500 A ANL type fuse View part →
589012 200 A ANL type fuse View part →
589064 Motor support bracket 185 TT View part →
589066 Motor support bracket 250 TT View part →
589096 Motor support bracket 140 TT View part →
589810 Gen2 ABS 12v View part →
589830 Gen2 ABS 24v Ask us to source it →
589811 Gen2 PS 24v/12v Ask us to source it →
589813 Gen2 PS 48v/24v Ask us to source it →

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.

Products in this Manual