Electric Specifications

Model V Motor W Typical max. pull Max. line speed Typical working load Current at working load Breaker supplied CSA (ISO 10133, 20 m) AWG (ABYC E11, 66 ft)
RX1800 12 700 850 kg / 1874 lb 29 m/min / 95 ft/min 213 kg / 470 lb 120 A 90 A 35 mm² 1
RX1800 24 900 850 kg / 1874 lb 29 m/min / 95 ft/min 213 kg / 470 lb 60 A 50 A 10 mm² 7
RX2200 12 1000 1025 kg / 2260 lb 39 m/min / 128 ft/min 257 kg / 567 lb 131 A 110 A 50 mm² 1
RX2200 24 1000 1025 kg / 2260 lb 39 m/min / 128 ft/min 257 kg / 567 lb 74 A 90 A 16 mm² 6
RX2500 12 1500 1175 kg / 2590 lb 40 m/min / 131 ft/min 294 kg / 648 lb 132 A 110 A 50 mm² 1
RX2500 24 1500 1175 kg / 2590 lb 40 m/min / 131 ft/min 294 kg / 648 lb 70 A 90 A 10 mm² 7

Values tested at +/- 10% on 12/24V systems. RX gypsies are designed for Lewmar chain; the RX is a chain windlass.

Gypsy & Chain Match

Gypsy Chain D mm / in P mm / in W mm / in
68120040 6 mm ISO 4565 6 / 0.236 18 / 0.709 21.6 / 0.85
6mm Din766 6 / 0.236 18.5 / 0.728 20.4 / 0.803
7mm ISO 4565 7 / 0.276 21 / 0.826 23 / 0.905
7mm Din766 7 / 0.276 22 / 0.866 23.8 / 0.937
1/4" G40 7 / 0.276 21.3 / 0.840 24.4 / 0.962
1/4" BBB 7.14 / 0.281 22.1 / 0.870 25.2 / 0.992
68120041 8 mm ISO 4565 8 / 0.315 24 / 0.945 28.8 / 1.134
5/16" G40 8.4 / 0.329 26.2 / 1.030 29.7 / 1.168
8 mm DIN 766 8 / 0.315 24 / 0.945 27.2 / 1.070
68120042 Lewmar 9.5mm G40 9.5 / 0.374 28 / 1.102 32 / 1.260
5/16" Campbell S3 8 / 0.315 32 / 1.260 28 / 1.102
3/8" Campbell S4 10 / 0.394 29 / 1.142 35 / 1.378
10 mm DIN 766 10 / 0.394 28 / 1.102 36 / 1.417
68120043 10 mm ISO 4565 10 / 0.394 30 / 1.181 36 / 1.417
Lewmar 9.5mm G40 9.5 / 0.374 28 / 1.102 32 / 1.260
3/8" Campbell S3 10 / 0.394 34.5 / 1.358 34.5 / 1.358

D = wire diameter, P = pitch, W = link width. If your chain does not match, ask before ordering a gypsy.

Preparation

  • Tools: 10 mm (3/8"), 14 mm (9/16") and 18 mm (3/4") drills, 46 mm (1 13/16") hole saw, crimping pliers, marine sealant.
  • Recommended minimum bulkhead (deck) thickness 40mm (1 1/2"); studs suit 40–50 mm (1 1/2"–2"). A thin-deck spacer 66100143 is available; thicker decks need a non-standard longer shaft.
  • Thin, foam or balsa-cored decks need reinforcement. A pad must keep the windlass base parallel to the motor/gearbox flange; shim before fitting the motor.
  • Lead from the roller horizontal to the top of the gypsy, on its centre line within ±5°, with enough vertical fall below (300 mm / 12" shown). Too little fall jams the chain.
  • Keep the motor/gearbox out of the chain fall.

Fitting

  • Holes: 3 × 10mm (3/8") for the studs, 14mm (9/16") and 18mm (3/4") for the sensors, two 46mm (1 13/16") holes for the motor/gearbox and the rode. Seal the cut edges.
  • Screw the studs into the base until they bottom out (flats nearest the base); studs 21Nm.
  • Base mat on deck, sealant optional; no permanent adhesive such as 5200; let rubbery sealant cure before final tightening.
  • Grease the shaft, check the drive key, slide the motor/gearbox up to the deck, check the faces are parallel; washer and M8 nut with Loctite® threadlock to 21Nm.
  • Loading: tie off the bitter end to a strong point in the locker, wrap the chain on the gypsy and power-load the rest.

The deck template guide is not a cutting template: check every hole before drilling and print the PDF at 100% if you work from it. Stripper ring vertical, viewed from the top.

Electrical

  • Cable length is battery + to the windlass and back to battery –, including breaker and switch gear; insulation rated 90°C or higher; tinned type III stranded copper with crimp terminals.
  • Breakers supplied: 50A (68000348), 70A (68000240), 90A (68000349), 110A (68000350). Fit close to the battery, dry and accessible; reset by hand after a trip.
  • Supplied with guarded rocker switch 68000593 and contactor 68000937 (12V) / 68000938 (24V). Multi-station switches wired in parallel.
  • Motor terminals: hold the back nut and tighten the M8 front nut to 15Nm to 18Nm. Motor connections D1 = F1, D2 = F2; control fuse 3 A.
Part no. Electrical item
68000348 Circuit breaker 50A View part →
68000240 Circuit breaker 70A View part →
68000349 Circuit breaker 90A View part →
68000350 Circuit breaker 110A View part →
68000593 Guarded rocker switch View part →
68000937 Contactor 12V View part →
68000938 Contactor 24V View part →
69000819 Wired remote 3M (2 button windlass & thruster) Ask us to source it →

Operation

  • Braked free-fall (gypsy only): isolate at the breaker, release the anchor locks, turn the gypsy cap anticlockwise with the handle and control the fall; tighten the cap fully once paid out. Remove the handle after use.
  • Power: DOWN to release, UP to retrieve, then secure the anchor to an independent strong point.
  • Optional manual recovery kit: 66120009.
  • Lay the rode under power as the boat falls back; motor up toward the anchor, never over and past it. Scope guide 7 to 1 (as printed).
  • Never leave the load on the windlass at anchor: chain stopper, bollard, sampson post or cleat.

Servicing & Troubleshooting

  • Regularly: fresh-water wash; clean and grease connections; keep the locker drain clear; check the gypsy (high wear) and grease the cone/gypsy faces on reassembly; check the studs after the first two or three recoveries (21Nm).
  • Annually: check cables; strip, clean and grease the above-deck parts; repaint any motor corrosion with marine oil-based enamel; blow the brush dust out without breathing it.
  • Gypsy change: stripper ring screw out with a 5mm Allen key, top cap, washer and upper cone off with the handle, gypsy out, refit cone and washer.
  • Rode pays out by itself: gypsy cap slack and rode not secured.
  • Sluggish: keep 13.5 Volts on 12 Volt systems (26.5 Volts on 24 Volt); check cable size, switches, battery, isolator, fuse and motor.

Kit List

RX Kits

Kit no. Description Items
66000799 Windlass handle 1 View part →
66100143 VX thin deck spacer 40 View part →
66120001 VX2/3 Go top cap replacement 3 Ask us to source it →
66120006 VX2/3 gypsy only drive kit 3, 6, 16, 23, 24, 25 View part →
66120009 VX2/3 Go manual recovery kit 2 View part →
66120011 VX2/3 stripper ring replacement 10 View part →
66120012 RMU50 IP cover kit 32, 33, 34, 35, 36, 37, 38, 39 Ask us to source it →
66120013 RX deck unit kit 8, 9, 15, 17, 22 Ask us to source it →
66120014 RX manual and kit 1, 18, 19, 20, 21 Ask us to source it →
68120031 VX2 motor g/box 700w 12v Sz50 IP assy 26, 32–39 Ask us to source it →
68120032 VX2 motor g/box 900w 24v Sz50 IP assy 27, 32–39 Ask us to source it →
68120033 VX2+ motor g/box 1000w 24v Sz50 IP assy 28, 32–39 Ask us to source it →
68120034 VX2+ motor g/box 1000w 12v Sz50 IP assy 29, 32–39 Ask us to source it →
68120035 VX3 motor g/box 1500w 12v Sz50 IP assy 30, 32–39 Ask us to source it →
68120036 VX3 motor g/box 1500w 24v Sz50 IP assy 31, 32–39 Ask us to source it →
68120040 Gypsy assy 6/7mm VX2/3 st/st 4, 5, 7, 10, 11 View part →
68120041 Gypsy assy 8mm VX2/3 st/st 4, 5, 7, 10, 12 View part →
68120042 Gypsy assy 10mm DIN VX2/3 st/st 4, 5, 7, 10, 13 Ask us to source it →
68120043 Gypsy assy 10mm ISO VX2/3 st/st 4, 5, 7, 10, 14 Ask us to source it →

Exploded View

Lewmar RX windlass exploded view

Several RX kits carry VX2/3 descriptions in the manual (as printed): the RX shares these parts with the VX range.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.