WIRING DIAGRAMS

How to wire the Lewmar thruster wireless receiver module into negative and positive switching TT thruster systems, and into a non-standard positive switching contactor system.

Lewmar Thruster Wireless Control — Wiring Diagrams

Which Diagram for Your Thruster

Diagram Used on Receiver connects Brown wires join
Negative switching, 12/24VDC 140TT 2.2KW; all 185TT, 250TT, 300TT To the thruster black box (via the automatic and/or P/S battery switch if fitted) Black (supply −)
Positive switching, 12VDC 140TT 2.0KW only To the thruster solenoid loom Red (supply +)
Positive switching, 12VDC – output wires reversed (temporary solution 18/04/08) 140TT 2.0KW only To the thruster solenoid loom Red (supply +)
Receiver in a non-standard positive switching system (temporary solution 18/04/08) Thruster or windlass with contactor or alternative control system Brown wires = positive switching outputs to the contactor Red (supply +), with Grey and Blue

Check whether your thruster switches the negative or the positive side before wiring: the only difference between the standard diagrams is where the two brown wires are joined.

Wireless Receiver Module Wires

No. Wire Function in the diagrams
1 Red To the red core of the control loom (supply +)
2 Black To the black core of the control loom (supply −)
3 Orange Not connected in the diagrams
4 Blue Config wire loop (left as a loop)
5 Long black Wireless antenna
6 Grey To the grey core of the control loom
7 Brown (two wires) Joined to the black (negative switching) or red (positive switching) core
8 Blue To the blue core of the control loom

Connection to the thruster control loom

Receiver / panel wire Thruster loom core
Grey Grey (Black-3)
Blue Blue (Black-2)
Red Red (Black-1)
Black Black (Grn/Yell)
  • The receiver is spliced into the cable between the thruster control panel and the thruster, at the control plug.
  • Non-standard positive switching system: power supply 12/24VDC, fused 5A max; Red to +, Black to −, Grey and Blue joined to the red (+) supply; the two Brown wires are the positive switching outputs to the contactor or alternative control system.

If the Thruster Runs the Wrong Way

  • On the reversed-output positive switching diagram and the non-standard positive switching diagram, the output wires are reversed, so the thruster (or windlass) may operate in the opposite direction.
  • To correct it, swap the Brown wires.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.