OWNER'S MANUAL

Tunnel sizing and siting, hub, saddle, propeller and motor installation torques, Gen 2 wiring, cable sizing, electrolytic test, operation, servicing, full specifications, dimensions and the parts lists for Lewmar TT tunnel thrusters 110TT to 300TT, electric and hydraulic.

DocumentLewmar TT Tunnel Thrusters 110TT–300TT (Gen 2) Owner's Manual
FormatPDF · 32 pages · 6.1 MB
LanguageEnglish
Lewmar TT Tunnel Thrusters 110TT–300TT (Gen 2) — Owner's Manual

This manual is split into 2 pages: Part 1 · Part 2 →

Electric Models – Weight & Specifications

Part No. Model Tunnel (mm) kW / HP Volt IP Gearbox Propeller Thrust kgf / lbs Weight kg / lbs Fuse – part no.
590000 TT 110 12v 110 1.5 / 2.0 12v Composite Single 5 blade 28 / 62 10 / 22 200A – 589012 Ask us to source it →
590001 TT 110 12v IP 110 1.5 / 2.0 12v IP Composite Single 5 blade 28 / 62 11 / 25 200A – 589012 Ask us to source it →
591251 TT 125 12v 125 2.0 / 2.7 12v Composite Single 5 blade 35 / 77 13 / 29 200A – 589012 Ask us to source it →
591252 TT 125 12v IP 125 2.0 / 2.7 12v IP Composite Single 5 blade 35 / 77 14 / 31 200A – 589012 Ask us to source it →
590002 TT 140 2.0kW 12v 140 2.0 / 2.7 12v Composite Single 5 blade 37 / 82 13 / 29 200A – 589012 Ask us to source it →
590003 TT 140 2.2kW 12v 140 2.2 / 3.0 12v Composite Single 5 blade 42 / 93 13 / 29 200A – 589012 View product →
590004 TT 140 2.0kW 12v IP 140 2.0 / 2.8 (as printed) 12v IP Composite Single 5 blade 37 / 82 14 / 31 200A – 589012 Ask us to source it →
590005 TT 140 2.2kW 12v IP 140 2.2 / 3.0 12v IP Composite Single 5 blade 42 / 93 14 / 31 200A – 589012 View product →
590006 TT 185 3.0kW 12v 185 3.0 / 4.0 12v St/st Single 5 blade 58 / 128 20 / 43 250 – 589008 View product →
590007 TT 185 3.0kW 24v 185 3.0 / 4.0 24v St/st Single 5 blade 58 / 128 20 / 43 130A – 589007 Ask us to source it →
590008 TT 185 4.0kW 12v 185 4.0 / 5.4 12v St/st Single 5 blade 65 / 143 20 / 43 400A – 589010 View product →
590009 TT 185 4.0kW 24v 185 4.0 / 5.4 24v St/st Single 5 blade 65 / 143 20 / 43 130A – 589007 View product →
590010 TT 185 5.0kW 12v 185 5.0 / 6.7 12v St/st Single 5 blade 82 / 181 27 / 59 400A – 589010 View product →
590011 TT 185 5.0kW 24v 185 5.0 / 6.7 24v St/st Single 5 blade 82 / 181 27 / 59 130A – 589007 View product →
590012 TT 185 6.0kW 12v 185 6.0 / 8.0 12v St/st Single 5 blade 97 / 214 27 / 59 500A – 589011 View product →
590013 TT 185 6.0kW 24v 185 6.0 / 8.0 24v St/st Single 5 blade 97 / 214 27 / 59 325A – 589009 View product →
590014 TT 185 3.0kW 12v IP 185 3.0 / 4.0 12v IP St/st Single 5 blade 58 / 128 21 / 47 250A – 589008 View product →
590015 TT 185 3.0kW 24v IP 185 3.0 / 4.0 24v IP St/st Single 5 blade 58 / 128 21 / 47 130A – 589007 Ask us to source it →
590016 TT 185 4.0kW 12v IP 185 4.0 / 5.4 12v IP St/st Single 5 blade 65 / 143 21 / 47 400A – 589010 View product →
590017 TT 185 4.0kW 24v IP 185 4.0 / 5.4 24v IP St/st Single 5 blade 65 / 143 21 / 47 130A – 589007 Ask us to source it →
590018 TT 185 5.0kW 12v IP 185 5.0 / 6.7 12v IP St/st Single 5 blade 82 / 181 28 / 62 400A – 589010 View product →
590019 TT 185 5.0kW 24v IP 185 5.0 / 6.7 24v IP St/st Single 5 blade 82 / 181 28 / 62 130A – 589007 Ask us to source it →
590020 TT 185 6.0kW 12v IP 185 6.0 / 8.0 12v IP St/st Single 5 blade 97 / 214 28 / 62 500A – 589011 Ask us to source it →
590021 TT 185 6.0kW 24v IP 185 6.0 / 8.0 24v IP St/st Single 5 blade 97 / 214 28 / 62 325A – 589009 Ask us to source it →
590022 TT 250 8.0kW 24v AL 250 8.0 / 10.8 24v Aluminium Twin CR 5 blade 140 / 308 46 / 101 400A – 589010 Ask us to source it →
590024 TT 250 8.0 24v 250 8.0 / 10.8 24v Bronze Twin CR 5 blade 140 / 308 46 / 101 400A – 589010 View product →
590025 TT 250 9.6 48v 250 9.6 / 13.0 48v Bronze Twin CR 5 blade 170 / 374 50 / 110 250A – 589008 View product →
590033 TT 300 10.8 24v AL 300 10.8 / 14.5 24v Aluminium Twin CR 5 blade 250 / 550 65 / 143 400A – 589010 View product →
590034 TT 300 10.8 24v 300 10.8 / 14.5 24v Bronze Twin CR 5 blade 250 / 550 65 / 143 500A – 589011 Ask us to source it →
590035 TT 300 15.0 48v 300 15.0 / 20.0 48v Bronze Twin CR 5 blade 280 / 616 68 / 150 400A – 589010 Ask us to source it →

Fuse holders listed in the table header: T1 – 589006, T2 – 589013. IP = ignition-protected version, required for damp or wet locations.

Hydraulic Models

Part No. Model Max output Motor disp. Delta Flow Max thrust
591820 185TTH 7 kW 6 cc/rev 210 bar 26 l/min 100 Kgf View product →
592520 250TTH 15 kW 26 cc/rev 122 bar 81.5 l/min 200 Kgf View product →
592521 250TTH 15 kW 17 cc/rev 190 bar 52.3 l/min 200 Kgf View product →
593020 300TTH 22.5 kW 30 cc/rev 182 bar 82.1 l/min 300 kgf View product →
593021 300TTH 22.5 kW 26 cc/rev 210 bar 71.7 l/min 300 Kgf View product →
Part No. Description Tunnel (mm) kW / HP Propeller Thrust kgf / lbs Weight kg / lbs
590054 TT 185 Hyd Gen 2 185 7.0 / 10.0 Single 5 blade 100 / 220 8 / 17.5
590055 TT 250 Hyd Gen 2 250 15.0 / 20.0 Twin CR 5 blade 200 / 240 (as printed) 13 / 28.5
590056 TT 300 Hyd Gen 2 300 22.5 / 30.0 Twin CR 5 blade 300 / 660 17 / 37.5

Dimensions

Choosing the Location

  • Hull work by a competent marine engineer, boat out of the water, levelled and secure in its cradle. The manual is based on a GRP tunnel.
  • As far forward as possible (lever effect).
  • 1 × Ø below the waterline to stop air being drawn into the tunnel (0.75 × Ø minimum); minimum 100 mm (4") as shown in the PDF figure.
  • Minimum suggested tunnel length 2 × Ø. Leave room inside for the thruster, motor and controls.
  • Tunnel entrances can be shaped (radius r = 0.1 Ø) to improve thrust and reduce noise.
  • Make a jig to align the holes on both sides, drill pilot holes, cut, fit the tube, grind off gel coat, fix the tunnel leaving room for the saddle, then gel coat and antifoul.

Recommended Tunnel

Model Inside Ø mm in Wall mm in
110 110 4 5/16 5.0 3/16
125 125 5 4.0–5.0 5/32 – 3/16
140 140 5 1/2 4.0–5.0 5/32 – 3/16
185 (3.0 & 4.0) 185 7 9/32 4.0–6.0 5/32 – 1/4
185 (5.0 & 6.0) 185 7 9/32 6.0 1/4
250 250 9 27/32 7.5 9/32
300 300 11 13/16 9.0 11/32

The recommended tunnel fits a Lewmar saddle and takes the weight of the thruster and the motor torque.

Installing Hub, Saddle, Propeller & Motor

  • The thruster can be installed at any angle within 90° from vertical. Electric motors more than 30° from vertical must be supported and strapped (motor support bracket, see accessories).
  • Normal installation puts the propeller to port (single-propeller units), to suit the wiring supplied. On 250TT/300TT fit the LH propeller on the port side.
  • Mark the saddle centre, then cut the hub hole with a GRP hole saw and light pressure; deburr, seal with resin and fair. Poor alignment affects hub position.
  • Hub gasket in place (it sets the propeller position). Zinc chromate paste or marine grease on the location bore; Sikaflex or similar may seal the saddle. Blue Loctite 243 on the bolts, then full torque within 10 minutes.
  • 185TT: check the gearbox leg stem in the saddle. Below 2 mm (1/16") remove tunnel material; above 3.5 mm (1/8") pack under the saddle.
  • Propeller stack, in order: large washer, propeller, anode, small washer, nyloc nut. Hold the blade with a length of wood against the tunnel to tighten.
  • Check the propeller is centred, turns freely and never touches the tunnel. Bronze hub and propeller can be antifouled; never antifoul the zinc anode.
  • Do not remove the drive-pin plastic retainer tie on the motor shaft (110TT–185TT); align the motor drive pin with the shaft slot and grease the hub shaft. 250TT/300TT: remove the drive shaft key retaining tie and grease the shaft.
  • Hydraulic: place the insulator between saddle and motor flange; the coupling is factory fitted (do not remove). Ports: 185TT main 3/8" BSPP; 250/300 main 3/4" BSPP, drain 1/4" BSPP. Insulated pipe sections help prevent corrosion.
Fastening 125TT / 140TT 185TT 250TT 300TT
Hub/saddle bolts 9 Nm (6.6 lb.ft) 21 Nm (15.5 lbs.ft) 33 Nm (24 lbs.ft) 82 Nm (60.5 lbs.ft)
Propeller nut 10 Nm (7.4 lbs.ft) (140) 15 Nm (11 lbs.ft) 35 Nm (26 lbs.ft) 35 Nm (26 lbs.ft)
Motor to saddle (electric) 20 Nm (15 lbs.ft) (140) 35 Nm (25.8 lbs.ft) – –

250TT/300TT: tighten each saddle bolt alternately, several times, up to full torque. Do not over-tighten propeller nuts.

Electrical Installation

110TT to 185TT

250TT & 300TT

Thruster loom pin Cable core Function
1 Brown +VE
2 Red Port contactor
3 Orange Stbd contactor
4 n/c n/c
5 Green Thermal switch
6 Blue −VE
  • The positive battery lead must go to the positive motor terminal, or the electronics can be damaged.
  • The ICU needs its own power supply. Do not remove the contactor cover unless authorised by Lewmar.
  • Thrust opposite to the control panel: swap the wire connections on the contactor coils.
  • Automatic battery switch (if fitted): 12v 589810, 24v 589830.
  • Fuse torque: 8 mm 12.5 Nm (9.2 lbf); 12 mm 21.5 Nm (15.9 lbf) (units as printed).
  • Motor studs: hold the stud with a second spanner (13 mm for 110TT, 125TT and 140TT; 17 mm for 185TT–300TT) and tighten to 20 Nm (15 lbs.ft). Do not over-tighten.
  • Ring terminals: 8 mm (5/16") for 140TT, 10 mm (3/8") for 185TT, 250TT and 300TT. Fit the insulating boots supplied; no bare wire may show.
  • Battery crank capacity at least equal to the thruster current; in-line fuse on the main cables; a battery switch that is off whenever the thruster is not in use or the boat is unoccupied.
  • Minimum voltage at the motor when running: 10V for 12V units, 21V for 24V units.

Cable sizes below are for the total run, battery to thruster and back, based on typical usage. Motor thermal trips must be wired in and the circuit protected by the recommended thermal breaker.

12V

24V

Electrolytic Test

  • The motor body and assembly must stay isolated from any supply or ground.
  • Test 1: negative disconnected, positive connected but battery switch off or fuse out. A continuity tester must show no connection between either stud and the motor body. +VE to body: look for cables touching or damage. −VE to body: remove any bonding straps and re-test.
  • Test 2: with the battery applied, measure between the −VE stud and the motor body. If you read supply voltage (12V / 24V), disconnect immediately and inspect.

Control Panel

  • 63.5 mm (2½") hole saw; check depth and access for the leads and plug (minimum 40 mm for the pads, 50 mm for the joysticks as shown in the PDF). Pre-installed seal, 4 screws supplied.
  • The small plug connects at the panel; for two or more panels use the Y connectors.
  • The auxiliary wire drives an automatic battery switch; ignore it if none is fitted.
  • On: hold ON for 1 second (green LED). Off: press ON once. In fault mode (solid red) pressing ON turns the system off.
  • With a second panel, pressing the opposite direction cancels thrust; the same direction has no effect.
LED Status
Green System ON
Amber Low voltage
Red (flashing) Motor high temperature
Red Fault

Safety Features & Final Checks

  • More than 3 minutes in one direction = fault mode (red). A PORT/STBD signal at switch-on = fault mode. PORT and STBD together = thrust stops.
  • Auto power-down after 15 minutes of inactivity (TT), 5 minutes (RT). Short delay on instant PORT/STBD reversal.
  • Motor thermal switch stops thrust and flashes the LED red until the motor cools.
  • Before power-up: all bolts tight, propellers fitted and nuts tightened, control box cover on, propellers turn freely; motor boots on, correct fuse, switch wires on the correct terminals.
  • Hydraulic: drain line fitted, fittings tight with seals, system pressures and flows set (see the system supplier).
  • Never run the thruster out of the water, even for a few seconds: the motor overspeeds by 300% and the warranty is void. Do not operate near swimmers.

Service Schedule

  • New installation: check the anode after about 3 – 4 months to set a replacement interval.
  • Annually: clear debris from tunnel, propeller and hub; replace the anode; replace a damaged or heavily fouled propeller; grease the exposed seal and shaft.
  • If the hub is removed, replace the tunnel gasket.
  • Check all leads tight, bolts at torque, motor dry and compartment watertight; clean the compartment.
  • Electric: brush carbon dust off the top of the motor, especially on aluminium boats (qualified electrician recommended). Hydraulic: see the system supplier.
  • Drive pin (110TT, 140TT, 185TT): cut the cable tie, punch out the old pin parts, tap in the new pin and secure with a new plastic cable tie.

Fault Finding

Symptom Check
Thrust in wrong direction Swap the contactor wires on the motor solenoid.
Fuse keeps blowing Wrong fuse rating; propeller restricted or jammed; propeller washer missing.
Control panel does not light Hold ON for 1 second; battery connected; main switch on and fuse OK; control loom connections; thermal switch tripped by long use: wait 20 minutes. Never cool the motor any other way.
Panel lit but no thrust Batteries charged? Main motor connections tight?
Poor thrust, or one direction only Undersized or flat batteries or cables (min 10V / 21V at the motor); tunnel or propeller blocked; propeller washers wrong; brush springs and brush contact.
Motor turns but no drive (140TT, 125TT, 185TT) Stop. Shear pin broken: remove the 4 motor bolts and replace the pin; or broken propeller blades.
Noisy, vibrating Propeller touching the tunnel; on 140–185 check the hub height.

Need a part that isn't listed? Ask us to source it and quote the part number from the PDF.

Products in this Manual